• 1

I-Managed Industrial Switch Metal Body Factory

Incazelo emfushane:

● isekela i-IGMP Snooping kanye nokuhlunga kwe-GMRP kwamaphakethe okuvimbela ukusakaza okuningi

● isekela imbobo ye-VLAN esekelwe embotsheni, i-IEEE 802.1Q VLAN nephrothokholi ye-GVRP, ukuhlela okulula kwenethiwekhi

● isekela i-QoS (IEEE 802.1p/1Q) kanye ne-TOS / DiffServ ukuze kukhuliswe ukuzinza kwenethiwekhi

● isekela i-stp / Rstp, i-SNMPv1 / v2 / v3 ukuze kuqinisekiswe ukuphepha kwenethiwekhi

● isebenzisa i-RMON ukuthuthukisa ikhono lokuqagela labaqaphi benethiwekhi

● isekela inethiwekhi yokukhala

● Isekela amandla okwenza isibuko sembobo ukuze kube lula ukulungisa iphutha ku-inthanethi


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

◎ incazelo yomkhiqizo

I-CF-HY808GW-SFP iyi-switch ye-Ethernet yezimboni yenethiwekhi esebenza kahle kakhulu, imikhiqizo ihlangabezana namazinga e-FCC, CE, ROHS.Inhlanganisela yokuxhumana ye-Ethernet esheshayo kanye ne-optical fibre interfaces, ene-interface engafika ku-16 kanye namachweba we-Gigabit afika kwangu-8, ithuthukisa ukuguquguquka kokuklama amanethiwekhi nezinhlelo zokusebenza.Lolu chungechunge lwama-switches asekela isibuko sechweba, i-VLAN, i-igmp, i-QoS, i-stp / i-Rstp nezinye izici zesofthiwe ecebile yesibili kanye nochungechunge lwezindlela zokuphatha ezisebenzayo, njenge-Web, i-SNMP kanye nokukhishwa kwe-alamu edluliselwe, okungcono kwe-automation yasefekthri, ukuthutha okuhlakaniphile. , ukubhekwa kwevidiyo kanye nezinye izinkambu zezicelo zezimboni ukuze kusungulwe inethiwekhi yokufinyelela yesiphetho esikude esisheshayo nezinzile ukuze kuhlinzekwe izixazululo eziphephile nezithembekile.

◎ izinkomba zobuchwepheshe bomkhiqizo

 

igama lomkhiqizo:

Ukushintsha izinga lezimboni

imodeli yomkhiqizo:

I-CF-HY808GW-SFP

Incazelo yembobo:

8 Izimbobo ze-RJ45 + 8 izimbobo ze-fiber optic optical

Imbobo ye-RJ45:

I-10 / 100 / 1000M Ukutholwa okuzenzakalelayo, i-adaptive egcwele / isigamu-duplex ye-MDI / MDI-X

Imbobo ye-Fiber:

Imbobo ye-1000BaseFX (SFP Slot)

I-Ethernet Standard:

IEEE802.3-10BaseT, IEEE802.3u-100BaseTX/100Base-FX, IEEE802.3x-Flow Control, IEEE802.3z-1000BaseLX, IEEE802.3ab-1000BaseTX.1000BaseTX, IEEEB1I-Procession80 I-Spanning Tree Protocol , IEEE802.I-1w-Rapid Spinning Tree Protoco, APS
Ukumaka kwe-IEEE802.1Q-VLAN, IEEE802.1p-Class of Service, IEEE802.1X-Port Based Network Access Control, nokunye

indawo yokusebenza:

Izinga lokushisa elisebenzayo: -40~85 °C (-40~185 °F) Izinga lokushisa lesitoreji: -40~85 °C (-40~185 °F) Umswakama ohlobene: 5%~95% (akukho ukuchayeka kwe-condensation)

izinga lomsebenzi:

I-EMI:FCC Ingxenye 15 Ingxenye Engaphansi B Ikilasi A, EN 55022 Ikilasi A
EMS :
I-IEC (EN) 61000-4-2 (ESD): ± 8kV ukukhishwa kokuxhumana, ± 15kV ukukhishwa komoya
I-IEC(EN)61000-4-3(RS):10V/m(80~1000MHz)
I-IEC (EN) 61000-4-4 (EFT): ikhebula lamandla: ± 4kV;ikhebula ledatha: ± 2kV
I-IEC (EN) 61000-4-5 (Surge): Intambo yamandla: ± 4kV CM / ± 2kV DM;ikhebula ledatha: ± 2kV
I-IEC (EN) 61000-4-6 (i-RF conduction): 3V (10kHz~150kHz), 10V (150kHz~80MHz)
I-IEC (EN) 61000-4-16 (i-co-mode conduction): 30V cont.300V,1s
I-IEC(EN )61000-4-8
Ukushaqeka: IEC 60068-2-27
I-Freefall: IEC 60068-2-32
Ukudlidliza: IEC 60068-2-6

Shintsha Izakhiwo:

Izinga lohlelo lokusebenza: isamba somkhawulokudonsa wendiza engemuva esitezi sesibili: 91.2GbpsUlayini obalulekile: 8 ububanzi be-VLAN ID: 1 ~ 4094

Ulayini obalulekile: 8 ububanzi be-VLAN ID: 1 ~ 4094

Inombolo yokusingatha: 512 Usayizi wethebula lekheli le-MAC: 16 K

Usayizi Webhafa Yephakheji: 8Mbits exchange latency <5us

Ukuphatha nokunakekela:

Usekelo lwekhonsoli, imodi yokuphatha iWEB
Ukusekelwa kwe-SNMP v1 / v2 / v3

ukuphepha kwenethiwekhi:

Sekela i-IEEE 802.1x Usekelo lwe-HTTP RADIUS
Ukusekela ukugreda komsebenzisi kusekela ukubophezela kwekheli le-MAC

umthombo:

I-voltage yokufaka: DC12-52V (isipele sokungadingeki kwamandla amabili)
Itheminali yokufinyelela: Itheminali yasePhoenixUsekelo lokungadingeki kokunikezwa kwamandla amabili
Usekelo lokuvikela okwakhelwe ngaphakathi komfula we-4.0A
Sekela isivikelo sokuvimbela ukuxhumana

izakhiwo zemishini:

Izindlu: Isigaba sokuvikela se-IP40, igobolondo lensimbi
Ubukhulu: 16614278mm
Isisindo: 1.25KG
Indlela yokufaka: ukufakwa kukaloliwe obambekile, ukufakwa okufakwe odongeni
Imodi yokukhipha ukushisa: ukupholisa kwemvelo, akukho fan

inqubo engafuneki:

Indandatho ye-ERPS isekelwa ngesikhathi sokuziphilisa <20ms Isekela i-STP / RSTP / MSTP
Ubuchwepheshe bokusingatha: Ukusekelwa kwe-IGMP v1 / v2 / v3, i-IGMP snooping
Sekela i-GMRP futhi usekele ukusekela kokusakaza okuningi okumile
imisebenzi yokushintshisana: Sekela umkhawulo wesivinini sechweba, ukusekela ukuhlangana kwechweba, ukusekela ukulawulwa kokugeleza kwechweba
Ukusekelwa kwamachweba i-VLAN, i-IEEE 802.1Q VLAN
Ukusekelwa kokucindezelwa kwesiphepho sokusakaza

I-metric ye-LED:

Isibani senkomba yokunikezwa kwamandla: PWR
Isibani senkomba ye-interface: imbobo kagesi, imbobo ekhanyayo (Isixhumanisi / UMTHETHO)

amazinga okuvikela:

IP40

ubufakazi:

Dlulisa isitifiketi: CE, FCC, Rohs, ISO9001:2008 Ministry of Industry and Information Technology Access Network License Umbiko Wokuhlola Ukuphepha Komphakathi
Ukuphepha: UL508

kusho isikhathi sephutha samahhala:

Amahora angu-300,000

Ukuqinisekisa ikhwalithi:

Iminyaka emihlanu

◎ usayizi wokubukeka komkhiqizo

Ubude x ububanzi x ubude (mm): 166x142x78mm

图片5

◎ umdwebo wohlelo lokusebenza lomkhiqizo

图片6

◎ oda ulwazi lwemodeli

imodeli

incazelo

I-CF-HY808GW-SFP

8 Gigabit light + 8 gigabit adaptive port, SFP interface, DC12-52V power supply-wide temperature (-40℃ -85℃) -CE-RoHS-FCC-Ministry of Public Security inspection report-Ministry of Industry and Information Technology access ilayisense

I-adaptha yamandla

I-CF12V1A-DC

I-12V / 1A, ilungele umugqa womkhiqizo wokushintshwa kwezimboni okungewona we-POE.

 

I-CF24V1A-DC

I-24V / 1A, ilungele ulayini womkhiqizo we-non-POE Industrial Switch.

 


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona

    Imikhiqizo ehlobene

    • Inethiwekhi yendandatho yepayipi yenethiwekhi enezingqimba ezintathu 40,000 trillion ukukhanya 16 ugesi 8 Gigabit Light Industrial Ethernet, switch

      Indandatho yenethiwekhi yepayipi yenethiwekhi enezingqimba ezintathu engu-40,000 tr...

      ◎ incazelo yomkhiqizo I-Industrial Ethernet switch (inguquko yezimboni ngamafuphi) iwuhlobo lwemishini yokuxhumana engabizi kakhulu ehlinzekwe ngokukhethekile ukuhlangabezana nezidingo zezicelo zezimboni eziguquguqukayo.Ngokwesidingo sangempela sokulawulwa kwezimboni, ukushintshwa kwezimboni kuxazulula izinkinga zobuchwepheshe ezifana nokuxhumana kwesikhathi sangempela, ukusebenza kokutholakala kwenethiwekhi nokuphepha.Uma kuqhathaniswa nokushintsha kwezentengiselwano ezejwayelekile, ukushintshwa kwezimboni kud...

    • I-6-port 10/100M/1000M L2 WEB Ephethwe I-Industrial Ethernet Shintsha Imodi Eyodwa ifayibha emibili

      I-6-port 10/100M/1000M L2 WEB Ephethwe Imboni ...

      I-6-port 10/100M/1000M L2 WEB Ephethwe I-Industrial Ethernet Shintshela Imodi Eyodwa Imodi yefayibha ekabili Izici Zomkhiqizo:  Ukufinyelela kwe-Gigabit, i-SFP fiber port uplink, umsebenzi we-Bypass ohlanganisiwe ◇ Isekela ukudlulisela phambili kwentambo okungavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Sekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-Gigabit SFP, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene.◇ Sekela imodi eyodwa ngokomzimba ...

    • I-6-port 10/100M/1000M L2 WEB Ephethwe I-Industrial Ethernet Shintsha ene-SFP interface

      I-6-port 10/100M/1000M L2 WEB Ephethwe Imboni ...

      I-6-port 10/100M/1000M L2 WEB Ephethwe I-Industrial Ethernet Shintsha ene-SFP interface Izici Zomkhiqizo:  Ukufinyelela kwe-Gigabit, i-SFP fiber port uplink, umsebenzi we-Bypass ohlanganisiwe ◇ Sekela ukudlulisela phambili kwentambo okungavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Sekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-Gigabit SFP, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene.◇ Sekela i-fibe eyodwa yemodi eyodwa...

    • I-12-port 10/100M/1000M L2+ I-Industrial Ethernet Switch

      I-12-port 10/100M/1000M L2+ Imboni Ephethwe ...

      I-12-port 10/100M/1000M L2+ Izici Zomkhiqizo Ophethwe I-Industrial Ethernet Switch:  Ukufinyelela kwe-Gigabit, i-SFP fiber port uplink, umsebenzi we-Bypass ohlanganisiwe ◇ Sekela ukudlulisela phambili kwe-wire-speed engavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Sekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-Gigabit SFP, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene.◇ Sekela indlela ye-fiber optical yemodi eyodwa yomzimba (Bypa...

    • I-Gigabit 2 optical 8 kagesi ye-SFP port switch management yezinga lezimboni ukuzwela okuphezulu

      I-Gigabit 2 optical 8 kagesi ye-SFP switch ...

      ◎ incazelo yomkhiqizo I-CF-HY2008GV-SFP iwuhlobo lokuphathwa kwenethiwekhi lokushintshwa kwe-Ethernet yezimboni, imikhiqizo ihlangabezana nezindinganiso ze-FCC, CE, RoHS.Sekela izimbobo ze-Gigabit ezi-2 nezingu-8 ze-Gigabit;ukusekela i-Ethernet yesingqimba sesibili sephrothokholi edingekayo endaweni yezimboni ukuze kuqinisekiswe ukuzinza kwenethiwekhi yokuxhumana;Lolu chungechunge lwamaswishi lusebenzisa amandla aphansi kanye nomklamo ongenabalandeli, luqinisekisa ukuthi akukho ukuphazamiseka komsindo, ukusekelwa-40 ~ 85℃ izinga lokushisa lokusebenza kanye ne-EMC enhle ehambisanayo kagesi...

    • Ukuphathwa kwenethiwekhi ye-WEB egcwele i-gigabit 2 light 8 power Industrial Ethernet, namaswishi

      Ukuphathwa kwenethiwekhi ye-WEB egcwele i-gigabit 2 ukukhanya 8 p...

      ◎ incazelo yomkhiqizo I-Industrial Ethernet switch (inguquko yezimboni ngamafuphi) iwuhlobo lwemishini yokuxhumana engabizi kakhulu ehlinzekwe ngokukhethekile ukuhlangabezana nezidingo zezicelo zezimboni eziguquguqukayo.Ngokwesidingo sangempela sokulawulwa kwezimboni, ukushintshwa kwezimboni kuxazulula izinkinga zobuchwepheshe ezifana nokuxhumana kwesikhathi sangempela, ukusebenza kokutholakala kwenethiwekhi nokuphepha.Uma kuqhathaniswa nokushintsha kwezentengiselwano ezejwayelekile, ukushintshwa kwezimboni kud...