• 1

I-Industrial Managed Switch

  • I-6-port 10/100M/1000M L2+ I-Industrial Ethernet Switch

    I-6-port 10/100M/1000M L2+ I-Industrial Ethernet Switch

    I-CF-HY2004GV-SFP iyiswishi egcwele ye-Gigabit L2+ elawulwa yizimboni ye-Ethernet fiber eyakhiwe ngokuzimela yi-CF FIBERLINK. Inamachweba angu-4*10/100/1000Base-T RJ45 kanye namachweba wefayibha angu-2*100/1000Base-X SFP. Imbobo ngayinye ingasekela ukudlulisela phambili isivinini sentambo. Iswishi ihlanganisa i-bypass optical switching module. Lapho ukunikezwa kwamandla komshini kuphazamiseka, i-fiber optical ishintshelwa ngokuzenzakalelayo esimweni sokudlula ukuze kugwenywe ukuphazamiseka kokuxhumana ngenxa yokwehluleka kokushintsha nokuqinisekisa ukwethembeka kokudluliswa kwenethiwekhi. I-CF-HY2004GV-SFP inomsebenzi wokuphatha inethiwekhi ye-L2+, isekela i-IPV4 yokudlulisela umzila omile, indlela ephelele yokuvikela ukuphepha, inqubomgomo ye-ACL/QoS nemisebenzi ecebile ye-VLAN, kulula ukuyiphatha nokuyinakekela. Sekela amaphrothokholi amaningi okuphinda asetshenziswe kabusha kwenethiwekhi i-STP/RSTP/MSTP(<50ms) ,Sekela umsebenzi wenethiwekhi yendandatho ye-ERPS (isikhathi sokuhlanganisa<20ms) ukuze kuthuthukiswe isipele sesixhumanisi nokuthembeka kwenethiwekhi ukuze kuqinisekiswe ukuxhumana okungaphazanyiswa kwezinhlelo zokusebenza ezibalulekile. Ngokwezidingo zangempela zohlelo lokusebenza, ukuphathwa kwekheli le-routing, ukuphathwa kwechweba, ukulawula ukugeleza kwechweba, ukuhlukaniswa kwe-VLAN, i-IGMP, inqubomgomo yezokuphepha nokunye ukulungiselelwa kwensiza yohlelo lokusebenza kwenziwa ngeWeb, CLI, SNMP, Telnet nezinye izindlela zokuphatha inethiwekhi. Igobolondo lenziwe nge-aluminium alloy, ekwazi ukuzivumelanisa nezimo zemvelo ezinhle kakhulu zemboni yezimboni (okuhlanganisa ukuzinza kwemishini, ukuguquguquka kwesimo sezulu, ukuguquguquka kwemvelo kagesi, njll.), izinga lokuvikela yi-IP40, lisekela ukuphakelwa kwamandla aphindwe kabili, ukusetshenziswa kwamandla aphansi futhi akukho fan, Iwaranti yeminyaka emi-5. Ilungele izimo zezimboni ezifana nezokuthutha ezihlakaniphile, ezokuthutha ngesitimela, imboni yamandla kagesi, izimayini, i-petroleum, ukuthunyelwa kwemikhumbi, i-metallurgy kanye nokwakhiwa kwamandla aluhlaza ukuze kusungulwe inethiwekhi yokuxhumana engabizi, ezinzile futhi enokwethenjelwa.

  • I-Uplink 36-port L3 Managed Industrial Ethernet Switch 4-Port 1/10G SFP

    I-Uplink 36-port L3 Managed Industrial Ethernet Switch 4-Port 1/10G SFP

    I-CF-HY4T2408S-SFP iyi-10G uplink L3 ephethwe yi-industrial Ethernet fiber switch eyakhiwe ngokuzimela yi-CF FIBERLINK. Inamachweba angu-24* 100/ 1000Base-X SFP kanye namachweba we-combo angu-8* 10/ 100/ 1000Base-T RJ45 kanye namachweba we-fiber slot angu-4* 1/ 10G SFP+. Imbobo ngayinye ingasekela ukudlulisela phambili isivinini sentambo. I-CF-HY4T2408S-SFP inomsebenzi wokuphatha inethiwekhi ye-L3, isekela ukuphathwa kwe-IPV4/IPV6, umzila oguquguqukayo wokudlulisa isivinini somugqa ogcwele, indlela ephelele yokuvikela ukuphepha, inqubomgomo ephelele ye-ACL/QoS, nemisebenzi ecebile ye-VLAN, kulula ukuyiphatha nokuyinakekela. Ngobuchwepheshe benethiwekhi yendandatho ehamba phambili embonini. Isekela izinqubo ezihlukahlukene zenethiwekhi yendandatho yezinga lezimboni, futhi ichweba ngalinye lingakha inethiwekhi yendandatho, inethiwekhi yendandatho esekelayo, inethiwekhi enezinkanyezi, inethiwekhi enezinkanyezi ezimbili, inethiwekhi yendandatho, inethiwekhi yendandatho ye-tangent, inethiwekhi yendandatho ephambanayo, inethiwekhi yendandatho ehlanganisiwe, ukuzelapha ngaphakathi kwe-ERPS <20ms yenethiwekhi yeringi. Uchungechunge lokushintshwa lunokwethenjelwa okuphezulu, ukuphepha okuphezulu, nokuphatha okuphezulu, kuqinisekisa ukudluliswa okuthembekile kwedatha ebalulekile, kusekela ukuphathwa okukude. Umkhiqizo ulandela ngokuphelele ukwakheka komkhiqizo wezimboni nezinto zokwakha. Igobolondo lenziwe ngezinto zensimbi ukuze kuthuthukiswe ukuchithwa kokushisa. Inokuvumelana nezimo okuhle kakhulu endaweni yezimboni (okubandakanya ukuzinza kwemishini, ukuguquguquka kwesimo sezulu, ukuguquguquka kwemvelo kagesi, njll.). Izinga lokuvikela lifinyelela ku-IP40 futhi lisekela ukuphakelwa kukagesi okubili okungafuneki okungu-2AC+DC, futhi i-MTBF ingakwazi ukufika eminyakeni engama-35, iwaranti yeminyaka emi-5. Ilungele ezokuthutha ezihlakaniphile, ezokuthutha ngesitimela, imboni kagesi, izimayini, i-petroleum, nezigcawu zezimboni ezifana nemikhumbi, i-metallurgy, nokwakhiwa kwamandla aluhlaza kwakha inethiwekhi yokuxhumana engabizi kakhulu, ezinzile, nethembekile.

  • I-10G Uplink 28-port L3 Managed Industrial Ethernet Switch 24 Gigabit port

    I-10G Uplink 28-port L3 Managed Industrial Ethernet Switch 24 Gigabit port

    I-CF-HY4T024G-SFP iyi-10G uplink L3 ephethwe yi-industrial Ethernet fiber switch eyakhiwe ngokuzimela yi-CF FIBERLINK. Inamachweba angu-24* 10/ 100/ 1000Base-T RJ45 kanye namachweba angu-4* 1/ 10G SFP+ we-fiber slot. Imbobo ngayinye ingasekela ukudlulisela phambili isivinini sentambo. I-CF-HY4T024G-SFP inomsebenzi wokuphatha inethiwekhi ye-L3, isekela ukuphathwa kwe-IPV4/IPV6, umzila oguquguqukayo wokudlulisela isivinini somugqa ogcwele, indlela yokuvikela ukuphepha ephelele, inqubomgomo ephelele ye-ACL/QoS, nemisebenzi ecebile ye-VLAN, kulula ukuyiphatha nokuyinakekela. Ngobuchwepheshe benethiwekhi yendandatho ehamba phambili embonini. Isekela izinqubo ezihlukahlukene zenethiwekhi yendandatho yezinga lezimboni, futhi ichweba ngalinye lingakha inethiwekhi yendandatho, inethiwekhi yendandatho esekelayo, inethiwekhi enezinkanyezi, inethiwekhi enezinkanyezi ezimbili, inethiwekhi yendandatho, inethiwekhi yendandatho ye-tangent, inethiwekhi yendandatho ephambanayo, inethiwekhi yendandatho ehlanganisiwe, ukuzelapha ngaphakathi kwe-ERPS <20ms yenethiwekhi yeringi. Uchungechunge lokushintshwa lunokwethenjelwa okuphezulu, ukuphepha okuphezulu, nokuphatha okuphezulu, kuqinisekisa ukudluliswa okuthembekile kwedatha ebalulekile, kusekela ukuphathwa okukude. Umkhiqizo ulandela ngokuphelele ukwakheka komkhiqizo wezimboni nezinto zokwakha. Igobolondo lenziwe ngezinto zensimbi ukuze kuthuthukiswe ukuchithwa kokushisa. Inokuvumelana nezimo okuhle kakhulu endaweni yezimboni (okubandakanya ukuzinza kwemishini, ukuguquguquka kwesimo sezulu, ukuguquguquka kwemvelo kagesi, njll.). Izinga lokuvikela lifinyelela ku-IP40 futhi lisekela ukuphakelwa kukagesi okubili okungafuneki okungu-2AC+DC, futhi i-MTBF ingakwazi ukufika eminyakeni engama-35, iwaranti yeminyaka emi-5. Ilungele ezokuthutha ezihlakaniphile, ezokuthutha ngesitimela, imboni kagesi, izimayini, i-petroleum, nezigcawu zezimboni ezifana nemikhumbi, i-metallurgy, nokwakhiwa kwamandla aluhlaza kwakha inethiwekhi yokuxhumana engabizi kakhulu, ezinzile, nethembekile.

  • I-10G Uplink 36-port L3 Ephethwe I-Industrial Ethernet Switch

    I-10G Uplink 36-port L3 Ephethwe I-Industrial Ethernet Switch

    I-CF-HY4T8024G-SFP iyi-10G uplink L3 ephethwe yi-industrial Ethernet fiber switch eyakhiwe ngokuzimela yi-CF FIBERLINK. Inamachweba angu-24* 10/ 100/ 1000Base-T RJ45 kanye namachweba we-combo angu-8* 100/ 1000Base-X SFP kanye namachweba we-fiber slot angu-4* 1/ 10G SFP+. Imbobo ngayinye ingasekela ukudlulisela phambili isivinini sentambo. I-CF-HY4T8024G-SFP inomsebenzi wokuphatha inethiwekhi ye-L3, isekela ukuphathwa kwe-IPV4/IPV6, umzila oguquguqukayo wokudlulisa isivinini somugqa ogcwele, indlela yokuvikela ukuphepha ephelele, inqubomgomo ephelele ye-ACL/QoS, nemisebenzi ye-VLAN ecebile, kulula ukuyiphatha nokuyinakekela. Ngobuchwepheshe benethiwekhi yendandatho ehamba phambili embonini. Isekela izinqubo ezihlukahlukene zenethiwekhi yendandatho yezinga lezimboni, futhi ichweba ngalinye lingakha inethiwekhi yendandatho, inethiwekhi yendandatho esekelayo, inethiwekhi enezinkanyezi, inethiwekhi enezinkanyezi ezimbili, inethiwekhi yendandatho, inethiwekhi yendandatho ye-tangent, inethiwekhi yendandatho ephambanayo, inethiwekhi yendandatho ehlanganisiwe, ukuzelapha ngaphakathi kwe-ERPS <20ms yenethiwekhi yeringi. Uchungechunge lokushintshwa lunokwethenjelwa okuphezulu, ukuphepha okuphezulu, nokuphatha okuphezulu, kuqinisekisa ukudluliswa okuthembekile kwedatha ebalulekile, kusekela ukuphathwa okukude. Umkhiqizo ulandela ngokuphelele ukwakheka komkhiqizo wezimboni nezinto zokwakha. Igobolondo lenziwe ngezinto zensimbi ukuze kuthuthukiswe ukuchithwa kokushisa. Inokuvumelana nezimo okuhle kakhulu endaweni yezimboni (okubandakanya ukuzinza kwemishini, ukuguquguquka kwesimo sezulu, ukuguquguquka kwemvelo kagesi, njll.). Izinga lokuvikela lifinyelela ku-IP40 futhi lisekela ukuphakelwa kukagesi okubili okungafuneki okungu-2AC+DC, futhi i-MTBF ingakwazi ukufika eminyakeni engama-35, iwaranti yeminyaka emi-5. Ilungele ezokuthutha ezihlakaniphile, ezokuthutha ngesitimela, imboni kagesi, izimayini, i-petroleum, nezigcawu zezimboni ezifana nemikhumbi, i-metallurgy, nokwakhiwa kwamandla aluhlaza kwakha inethiwekhi yokuxhumana engabizi kakhulu, ezinzile, nethembekile.

  • 28-port 10G Uplink L3 Ephethwe I-Industrial Ethernet Switch

    28-port 10G Uplink L3 Ephethwe I-Industrial Ethernet Switch

    I-CF-HY4T8016G-SFP iyi-10G uplink L3 ephethwe yi-industrial Ethernet fiber switch eyakhiwe ngokuzimele yi-CF FIBERLINK. Inamachweba angu-16* 10/ 100/ 1000Base-T RJ45 kanye namachweba angu-8* 100/ 1000Base-X SFP kanye namachweba angu-4* 1/ 10G SFP+ we-fiber slot. Imbobo ngayinye ingasekela ukudlulisela phambili isivinini sentambo. I-CF-HY4T8016G-SFP inomsebenzi wokuphatha inethiwekhi ye-L3, isekela ukuphathwa kwe-IPV4/IPV6, umzila oguquguqukayo wokudlulisa isivinini somugqa ogcwele, indlela ephelele yokuvikela ukuphepha, inqubomgomo ephelele ye-ACL/QoS, nemisebenzi ye-VLAN ecebile, kulula ukuyiphatha nokuyinakekela. Ngobuchwepheshe benethiwekhi yendandatho ehamba phambili embonini. Isekela izinqubo ezihlukahlukene zenethiwekhi yendandatho yezinga lezimboni, futhi ichweba ngalinye lingakha inethiwekhi yendandatho, inethiwekhi yendandatho esekelayo, inethiwekhi enezinkanyezi, inethiwekhi enezinkanyezi ezimbili, inethiwekhi yendandatho, inethiwekhi yendandatho ye-tangent, inethiwekhi yendandatho ephambanayo, inethiwekhi yendandatho ehlanganisiwe, ukuzelapha ngaphakathi kwe-ERPS <20ms yenethiwekhi yeringi. Uchungechunge lokushintshwa lunokwethenjelwa okuphezulu, ukuphepha okuphezulu, nokuphatha okuphezulu, kuqinisekisa ukudluliswa okuthembekile kwedatha ebalulekile, kusekela ukuphathwa okukude. Umkhiqizo ulandela ngokuphelele ukwakheka komkhiqizo wezimboni nezinto zokwakha. Igobolondo lenziwe ngezinto zensimbi ukuze kuthuthukiswe ukuchithwa kokushisa. Inokuvumelana nezimo okuhle kakhulu endaweni yezimboni (okubandakanya ukuzinza kwemishini, ukuguquguquka kwesimo sezulu, ukuguquguquka kwemvelo kagesi, njll.). Izinga lokuvikela lifinyelela ku-IP40 futhi lisekela ukuphakelwa kukagesi okubili okungafuneki okungu-2AC+DC, futhi i-MTBF ingakwazi ukufika eminyakeni engama-35, iwaranti yeminyaka emi-5. Ilungele ezokuthutha ezihlakaniphile, ezokuthutha ngesitimela, imboni kagesi, izimayini, i-petroleum, nezigcawu zezimboni ezifana nemikhumbi, i-metallurgy, nokwakhiwa kwamandla aluhlaza kwakha inethiwekhi yokuxhumana engabizi kakhulu, ezinzile, nethembekile.

  • Inethiwekhi eyindandatho yokuphatha inethiwekhi yezingqimba ezintathu 40000 ukukhanya 24 gigabit kagesi 8 I-Combo port industrial switch

    Inethiwekhi eyindandatho yokuphatha inethiwekhi yezingqimba ezintathu 40000 ukukhanya 24 gigabit kagesi 8 I-Combo port industrial switch

    ● Nikeza 2410 / 100 / 1000M izimbobo zikagesi eziguqukayo ezingu-RJ 45 nezimbobo ezingu-4 zamagigabhithi e-SFP,

    8 amachweba we-Gigabit SFP Combo amaningi.

    ● Sekela iphrothokholi ye-IEEE 802.1Q VLAN ne-GVRP, ukuhlela okulula kwenethiwekhi

    ● Ukufakwa kwamandla kagesi okubanzi: okokufaka kwamandla okukabili (AC: 100-240V 50 / 60Hz; DC: 36-72V), kuthuthukisa kakhulu ukuthembeka kokuphakelwa kwamandla kwemikhiqizo

    ● Ukusekelwa kwephrothokholi yesihlahla se-STP / RSTP / MSTP, i-SNMPv1 / v2 / v3, ukuqinisekisa ukuphepha kwenethiwekhi

    ● Usekelo lobuchwepheshe bokuvikela izindandatho eziningi ze-ERPS Ethernet, isikhathi sokuhlangana kwenethiwekhi esingu-20ms

    ● Sekela umsebenzi wesibuko sembobo, ukulungisa iphutha ku-inthanethi kalula

    ● Sekela umkhawulo wejubane lechweba, ukucindezela kwesiphepho sokusakaza, ukucindezelwa kwesiphepho esisakazwa ngeningi, ukucindezela okungaziwa kwesiphepho se-unicast

    ● Ukuphathwa kokuphepha: Sekela uhlu lokulawula ukufinyelela kwe-ACL, isekela i-802.1X, isekela ukuphathwa kwesigaba somsebenzisi
    ● Umsebenzi wokuphatha: i-WEB yokusekela, i-CLI, imodi yokuphatha ye-SNMP
    ● Ukuqapha nokunakekela: sekela isibuko sembobo, ukuqapha isimo sokusebenzelana, nokuphathwa kwelogi
    ● Ukusebenzisa idizayini yesekethe yokushabalalisa ukushisa kwefeni, igobolondo le-aluminium ingxubevange, ukufakwa kohlobo lwesitimela esingumhlahlandlela.

  • Inethiwekhi yenethiwekhi yokuphatha inethiwekhi yesitezi esigcwele i-gigabit 4 light 8 kagesi I-Industrial Ethernet, kanye namaswishi

    Inethiwekhi yenethiwekhi yokuphatha inethiwekhi yesitezi esigcwele i-gigabit 4 light 8 kagesi I-Industrial Ethernet, kanye namaswishi

    ● Nikeza ngezimbobo zikagesi eziguqukayo ezingu-810 / 100 / 1000M RJ 45 nezimbobo ezingu-4 ze-Gigabit SFP

    ● Sekela iphrothokholi ye-IEEE 802.1Q VLAN ne-GVRP, ukuhlela okulula kwenethiwekhi

    ● Okokufaka kwamandla kagesi abanzi: 9.6V~60VDC isipele sokuphindaphindeka kokudluliselwa kwamandla okubili, kuthuthukisa kakhulu ukuthembeka kokuphakelwa kwamandla komkhiqizo

    ● Ukusekelwa kwephrothokholi yesihlahla se-STP / RSTP / MSTP, i-SNMPv1 / v2 / v3, ukuqinisekisa ukuphepha kwenethiwekhi

    ● Usekelo lobuchwepheshe bokuvikela izindandatho eziningi ze-ERPS Ethernet, isikhathi sokuhlangana kwenethiwekhi esingu-20ms

    ● Sekela umsebenzi wesibuko sembobo, ukulungisa iphutha ku-inthanethi kalula

    ● Sekela umkhawulo wejubane lechweba, ukucindezela kwesiphepho sokusakaza, ukucindezelwa kwesiphepho esisakazwa ngeningi, ukucindezela okungaziwa kwesiphepho se-unicast

    ● Ukuphathwa kokuphepha: Sekela uhlu lokulawula ukufinyelela kwe-ACL, isekela i-802.1X, isekela ukuphathwa kwesigaba somsebenzisi
    ● Umsebenzi wokuphatha: i-WEB yokusekela, i-CLI, imodi yokuphatha ye-SNMP
    ● Ukuqapha nokunakekela: sekela isibuko sembobo, ukuqapha isimo sokusebenzelana, nokuphathwa kwelogi
    ● Ayikho idizayini yesekethe yokushabalalisa ukushisa kwefeni, igobolondo le-aluminium ingxubevange, ukufakwa kohlobo lwesitimela somhlahlandlela.

  • Ukuphathwa kwenethiwekhi ye-WEB egcwele i-gigabit 2 light 8 power Industrial Ethernet, namaswishi

    Ukuphathwa kwenethiwekhi ye-WEB egcwele i-gigabit 2 light 8 power Industrial Ethernet, namaswishi

    ● Nikeza ngembobo kagesi eguqukayo engu-810 / 100 / 1000M RJ 45 nezimbobo ezingu-2 ze-Gigabit SFP

    ● Sekela iphrothokholi ye-IEEE 802.1Q VLAN ne-GVRP, ukuhlela okulula kwenethiwekhi

    ● Okokufaka kwamandla kagesi abanzi: DC12-57V isipele esingasadingeki sokudluliselwa kwamandla kagesi, sithuthukisa kakhulu ukuthembeka kokuphakelwa kwamandla komkhiqizo

    ● Ukusekelwa kwephrothokholi yesihlahla se-STP / RSTP / MSTP, i-SNMPv1 / v2 / v3, ukuqinisekisa ukuphepha kwenethiwekhi

    ● Sekela ukuphathwa kwenethiwekhi ye-WEB, uhlobo lwesitimela esingumhlahlandlela, ukuvikelwa kombani okungu-6KV.

    ● Sekela umsebenzi wesibuko sembobo, ukulungisa iphutha ku-inthanethi kalula

    ● Sekela umkhawulo wejubane lechweba, ukucindezela kwesiphepho sokusakaza, ukucindezelwa kwesiphepho esisakazwa ngeningi, ukucindezela okungaziwa kwesiphepho se-unicast

    ● Ukuphathwa kokuphepha: Sekela uhlu lokulawula ukufinyelela kwe-ACL, isekela i-802.1X, isekela ukuphathwa kwesigaba somsebenzisi
    ● Umsebenzi wokuphatha: i-WEB yokusekela, i-CLI, imodi yokuphatha ye-SNMP
    ● Ukuqapha nokunakekela: sekela isibuko sembobo, ukuqapha isimo sokusebenzelana, nokuphathwa kwelogi
    ● Idizayini yesekethe yokupholisa engena fan, igobolondo le-aluminium ingxubevange.

  • Umhlinzeki We-Chip Yezimboni Ephethwe

    Umhlinzeki We-Chip Yezimboni Ephethwe

    ● isekela i-IGMP Snooping kanye nokuhlunga kwe-GMRP kwamaphakethe okuvimbela ukusakaza okuningi

    ● isekela imbobo ye-VLAN esekelwe embotsheni, i-IEEE 802.1Q VLAN nephrothokholi ye-GVRP, ukuhlela okulula kwenethiwekhi

    ● isekela i-QoS (IEEE 802.1p/1Q) kanye ne-TOS / DiffServ ukuze kukhuliswe ukuzinza kwenethiwekhi

    ● isekela i-stp / Rstp, i-SNMPv1 / v2 / v3 ukuze kuqinisekiswe ukuphepha kwenethiwekhi

    ● isebenzisa i-RMON ukuthuthukisa ikhono lokuqagela labaqaphi benethiwekhi

    ● Isekela inethiwekhi yeringitho ye-ERPS

    ● Isekela amandla okwenza isibuko sembobo ukuze kube lula ukulungisa iphutha ku-inthanethi

    ● isekela umkhawulo wejubane lechweba, ukucindezela isiphepho sokusakaza, ukucindezelwa kwesiphepho esisakazwa kaningi, kanye nokucindezela okungaziwa kwe-unicast storm

    ● Ukuphathwa kwezokuphepha: kusekela uhlu lokulawula ukufinyelela kwe-ACL, 802.1X, nokuphathwa kwesigaba somsebenzisi

  • I-Managed Industrial Switch Metal Body Factory

    I-Managed Industrial Switch Metal Body Factory

    ● isekela i-IGMP Snooping kanye nokuhlunga kwe-GMRP kwamaphakethe okuvimbela ukusakaza okuningi

    ● isekela imbobo ye-VLAN esekelwe embotsheni, i-IEEE 802.1Q VLAN nephrothokholi ye-GVRP, ukuhlela okulula kwenethiwekhi

    ● isekela i-QoS (IEEE 802.1p/1Q) kanye ne-TOS / DiffServ ukuze kukhuliswe ukuzinza kwenethiwekhi

    ● isekela i-stp / Rstp, i-SNMPv1 / v2 / v3 ukuze kuqinisekiswe ukuphepha kwenethiwekhi

    ● isebenzisa i-RMON ukuthuthukisa ikhono lokuqagela labaqaphi benethiwekhi

    ● isekela inethiwekhi yokukhala

    ● Isekela amandla okwenza isibuko sembobo ukuze kube lula ukulungisa iphutha ku-inthanethi

  • I-Gigabit 2 optical 4 yembobo kagesi ye-SFP ye-PoE shintsha ukuphathwa kwenethiwekhi kwezinga lokuvikelwa kombani kwezimboni

    I-Gigabit 2 optical 4 yembobo kagesi ye-SFP ye-PoE shintsha ukuphathwa kwenethiwekhi kwezinga lokuvikelwa kombani kwezimboni

    ● isekela i-IGMP Snooping kanye nokuhlunga kwe-GMRP kwamaphakethe okuvimbela ukusakaza okuningi

    ● isekela imbobo ye-VLAN esekelwe embotsheni, i-IEEE 802.1Q VLAN nephrothokholi ye-GVRP, ukuhlela okulula kwenethiwekhi

    ● isekela i-QoS (IEEE 802.1p/1Q) kanye ne-TOS / DiffServ ukuze kukhuliswe ukuzinza kwenethiwekhi

    ● isekela i-stp / Rstp, i-SNMPv1 / v2 / v3 ukuze kuqinisekiswe ukuphepha kwenethiwekhi

    ● I-RMON isebenzisa i-RMON ukuthuthukisa amandla okuqagela amamonitha enethiwekhi

    ● Isekela inethiwekhi yeringitho ye-ERPS

    ● Isekela amandla okwenza isibuko sembobo ukuze kube lula ukulungisa iphutha ku-inthanethi

    ● isekela umkhawulo wejubane lechweba, ukucindezela isiphepho sokusakaza, ukucindezelwa kwesiphepho esisakazwa kaningi, kanye nokucindezela okungaziwa kwe-unicast storm

    ● Ukuphathwa kwezokuphepha: kusekela uhlu lokulawula ukufinyelela kwe-ACL, 802.1X, nokuphathwa kwesigaba somsebenzisi

  • I-Gigabit 2 optical 8 kagesi ye-SFP port switch management yezinga lezimboni ukuzwela okuphezulu

    I-Gigabit 2 optical 8 kagesi ye-SFP port switch management yezinga lezimboni ukuzwela okuphezulu

    ● isekela i-IGMP Snooping

    ● isekela imbobo ye-VLAN esekelwe ku-Port, i-IEEE 802.1Q VLAN, ukuhlela okulula kwenethiwekhi

    ● isekela i-QoS (IEEE 802.1p/1Q) kanye ne-TOS / DiffServ ukuze kukhuliswe ukuzinza kwenethiwekhi

    ● isekela i-stp / Rstp, i-SNMPv1 / v2 / v3 ukuze kuqinisekiswe ukuphepha kwenethiwekhi

    ●I-RMON isebenzisa i-RMON ukuthuthukisa amandla okuqagela amamonitha enethiwekhi

    ●Isekela amandla okwenza isibuko sembobo ukuze kube lula ukulungisa iphutha ku-inthanethi

    ● isekela umkhawulo wejubane lechweba, ukucindezela isiphepho sokusakaza, ukucindezelwa kwesiphepho esisakazwa kaningi, kanye nokucindezela okungaziwa kwe-unicast storm

    ● Ukuphathwa kwezokuphepha: kusekela uhlu lokulawula ukufinyelela kwe-ACL, 802.1X, nokuphathwa kwesigaba somsebenzisi
    ● umsebenzi wokuphatha: i-WEB yokusekela, imodi yokuphatha ye-SNMP
    ● ukuqapha nokunakekela: isibuko sechweba sisekela amachweba, ukuqapha isimo sokusebenzelana, ukuphathwa kwelogi