• 1

I-10G Uplink 28-port L3 Managed Industrial Ethernet Switch 24 Gigabit port

Incazelo emfushane:

I-CF-HY4T024G-SFP iyi-10G uplink L3 ephethwe yi-industrial Ethernet fiber switch eyakhiwe ngokuzimela yi-CF FIBERLINK.Inamachweba angu-24* 10/ 100/ 1000Base-T RJ45 kanye namachweba angu-4* 1/ 10G SFP+ we-fiber slot.Imbobo ngayinye ingasekela ukudlulisela phambili isivinini sentambo.I-CF-HY4T024G-SFP inomsebenzi wokuphatha inethiwekhi ye-L3, isekela ukuphathwa kwe-IPV4/IPV6, umzila oguquguqukayo wokudlulisela isivinini somugqa ogcwele, indlela yokuvikela ukuphepha ephelele, inqubomgomo ephelele ye-ACL/QoS, nemisebenzi ecebile ye-VLAN, kulula ukuyiphatha nokuyinakekela.Ngobuchwepheshe benethiwekhi yendandatho ehamba phambili embonini.Isekela izinqubo ezihlukahlukene zenethiwekhi yendandatho yezinga lezimboni, futhi ichweba ngalinye lingakha inethiwekhi yendandatho, inethiwekhi yendandatho esekelayo, inethiwekhi enezinkanyezi, inethiwekhi enezinkanyezi ezimbili, inethiwekhi yendandatho, inethiwekhi yendandatho ye-tangent, inethiwekhi yendandatho ephambanayo, inethiwekhi yendandatho ehlanganisiwe, ukuzelapha ngaphakathi kwe-ERPS <20ms yenethiwekhi yeringi.Uchungechunge lokushintshwa lunokwethenjelwa okuphezulu, ukuphepha okuphezulu, nokuphatha okuphezulu, kuqinisekisa ukudluliswa okuthembekile kwedatha ebalulekile, kusekela ukuphathwa okukude.Umkhiqizo ulandela ngokuphelele ukwakheka komkhiqizo wezimboni nezinto zokwakha.Igobolondo lenziwe ngezinto zensimbi ukuze kuthuthukiswe ukuchithwa kokushisa.Inokuvumelana nezimo okuhle kakhulu endaweni yezimboni (okubandakanya ukuzinza kwemishini, ukuguquguquka kwesimo sezulu, ukuguquguquka kwemvelo kagesi, njll.).Izinga lokuvikela lifinyelela ku-IP40 futhi lisekela ukuphakelwa kukagesi okubili okungafuneki okungu-2AC+DC, futhi i-MTBF ingakwazi ukufika eminyakeni engama-35, iwaranti yeminyaka emi-5.Ilungele ezokuthutha ezihlakaniphile, ezokuthutha ngesitimela, imboni kagesi, izimayini, i-petroleum, nezigcawu zezimboni ezifana nemikhumbi, i-metallurgy, nokwakhiwa kwamandla aluhlaza kwakha inethiwekhi yokuxhumana engabizi kakhulu, ezinzile, nethembekile.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

I-28-port 10G Uplink 28-port L3 Ephethwe I-Industrial Ethernet Switch

Izici Zomkhiqizo:

Ukufinyelela kwe-Gigabit, i-10G uplink

◇ Sekela ukudlulisa okungavimbeli kwe-wire-speed.

◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.

◇ Isekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-10G SFP+ uplink, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene.

 Ukuphepha

◇ Ukusekela ukuhlukaniswa kwembobo.

◇ Sekela imbobo yokusakaza ukucindezelwa kwesiphepho.

◇ Sekela i-IP+MAC+port+VLAN umsebenzi wokubophezela ovumelana nezimo kane we-IP+MAC.

◇ Isekela 802. Ukuqinisekisa okungu-1X ukuze kuhlinzekwe imisebenzi yokuqinisekisa yamakhompyutha e-LAN, nokulawula isimo sokugunyazwa sezimbobo ezilawulwayo ngokuya ngemiphumela yokuqinisekisa.

 Amandla aqinile wokucubungula ibhizinisi

◇ Sekela inethiwekhi yeringi ye-ERPS kanye ne-STP/RSTP/MSTP ukuze kuqedwe izihibe eziyisi-2 futhi ubone isipele sesixhumanisi.

◇ Sekela i-IEEE802.I-1Q VLAN, Abasebenzisi bangahlukanisa kalula i-VLAN, i-Voice VLAN, ne-QinQ ukucushwa ngokwezidingo zabo.

◇ Sekela ukuhlanganisa okumile nokuguquguqukayo ukuze ukhulise ngempumelelo umkhawulokudonsa wesixhumanisi, qaphela

 ukulinganisa kokulayisha, xhumanisa ikhophi yasenqolobaneni, futhi uthuthukise ukuthembeka kwesixhumanisi.

◇ Isekela i-QoS, i-port-based, 802. Izindlela ezintathu ezibalulekile ezisekelwe ku-1P kanye ne-DSCP kanye nezindlela zokusebenza ezine zokuhlela ulayini: Equ, SP, WRR, kanye ne-SP+WRR.

◇ Sekela i-ACL ukuthi ihlunge amaphakethe edatha ngokulungiselela ukusebenza kokucubungula umthetho okufanayo nezimvume zesikhathi, futhi inikeze izinqubomgomo ezivumelana nezimo zokulawula ukufinyelela kokuvikeleka.

◇ Isekela iphrothokholi ye-IGMP V1/V2/V3 yokusakaza okuningi, i-IGMP Snooping ihlangabezana nezimfuneko zokugadwa kwevidiyo ezinencazelo ephezulu kanye nezidingo zokufinyelela kwinkomfa yevidiyo.

 Izinzile futhi zithembekile

◇ CCC, CE, FCC, RoHS.

◇ Ukusetshenziswa kwamandla okuphansi, Ayikho ifeni, igobolondo le-aluminium.

◇ Iphaneli elisebenziseka kalula lingabonisa isimo sedivayisi ngesibonisi se-LED se-PWR,Isixhumanisi.

◇ Ukunikezwa kwamandla okuthuthukisiwe, idizayini ephezulu yokuphinda ingasebenzi, ihlinzeka ngokuphuma kwamandla kwesikhathi eside nokuzinzile.

 Ukusebenza okulula nokuphathwa kokulungiswa

◇ Sekela ukuqapha kwe-CPU, ukuqapha inkumbulo, ukutholwa kwe-Ping, ukutholwa kobude bekhebula.

◇ Sekela i-HTTPS, i-SSLV3, i-SSHV1/V2 nezinye izindlela zokubethela, okwenza ukuphatha kuvikeleke kakhulu.

◇ Sekela i-RMON, ilogi yesistimu, kanye nezibalo zethrafikhi yechweba ukuze kube lula ukwenziwa ngcono kwenethiwekhi noshintsho.

◇Sekela i-LLDP ukwenza lula uhlelo lokuphatha inethiwekhi ukuze ubuze futhi wahlulele isimo sokuxhumana sesixhumanisi.

◇Sekela ukuphathwa kwenethiwekhi yewebhu, ulayini womyalo we-CLI (i-Console, i-Telnet), i-SNMP (V1/V2/V3) nokunye ukuphatha nokugcinwa okuhlukahlukene.

Ipharamitha yezobuchwepheshe:

 Imodeli  Idatha ye-CF-HY4T024G-SFP
 Izici zesixhumi esibonakalayo
  Imbobo Elungisiwe  4* 1/10G uplink SFP+ amachweba24* 10/ 100/ 1000Base-T RJ45 amachweba1*I-Console port
 Imbobo ye-Ethernet  I-Port 1-24 isekela i-10/ 100/ 1000Base-T(X) inzwa ngokuzenzakalelayo, i-duplex egcwele/uhhafuUkuzijwayeza kwe-MDI/MDI-X
  Ibhangqa ElisontekileUkudluliswa  10BASE-T: Cat3,4,5 UTP(≤100 amamitha)100BASE-TX: Cat5 noma kamuva UTP(≤100 amamitha)1000BASE-T: Cat5e noma kamuva UTP(≤100 amamitha)
  SFP Slot Port  I-Gigabit SFP optical fiber port kanye ne-10G SFP+ optical fiber port, inombolo ezenzakalelayofaka amamojula okubona (okungakhethwa kukho imodi eyodwa / imodi eminingi, i-fibre eyodwa / imojuli ye-fiber optical ekabili. LC)
 Ukunwetshwa kwechweba le-SFP  I-Turbo overclocking 2.5G module optical kanye nendandatho
I-Wavelength/Ibanga Imodi eminingi: 850nm / 0-550M( 1G), 850nm /0-300M( 10G),Imodi eyodwa: 1310nm / 0-40KM, 1550nm / 0- 120KM.
 Ipharamitha ye-Chip
 InethiwekhiUhlobo Lokuphatha   L3
 Inethiwekhi yokukhala Isekela umsebenzi wenethiwekhi yendandatho ye-ERPS, enenani eliphezulu lezindandatho ezingu-5 kanye nesikhathi sokuhlangana esingu-<20ms
 Iphrothokholi Yenethiwekhi IEEE802.3 10BASE-T, IEEE802.3i 10Base-T, IEEE802.3u 100Base-TXIEEE802.3ab 1000Base-T, IEEE802.3z 1000Base-X, IEEE802.3ae10GBase-LR/SR, IEEE802.3x
 Imodi yokudlulisa  Gcina bese udlulisela phambili(Isivinini socingo esigcwele)
 Ukushintsha Amandla  128Gbps
 Imemori ye-Buffer  96Mpps
 I-MAC  32K
Isibonisi se-LED  I-PowerIndicatorLight  P:1 Green
I-Fiber Indicator Light F: 1 Okuluhlaza (Isixhumanisi, SDFED)
Esihlalweni se-RJ45  Okuphuzi:Khombisa i-PoE
Okuluhlaza: Ibonisa isimo sokusebenza senethiwekhi
Setha kabusha Ukushintsha  Yebo, Cindezela futhi ubambe iswishi yokusetha kabusha ama-10s futhi uyikhulule ukuze ubuyisele ifayelaizilungiselelo zefekthri 
Amandla
I-Voltage esebenzayo  I-DC36-72V, itheminali ye-Phoenix eyi-Pin engu-4, isekela ukuvikela okuphambene nokuhlehla
 Ukusetshenziswa kwamandla  Okulindile<35W, Umthwalo ogcwele<45W
Ukunikezwa kwamandla kagesi  I-AC100-240V 50/60Hz ukunikezwa kwamandla kwezimboni
Isitifiketi & Iwaranti
UmbaniUkuvikelwa  Ukuvikelwa kombani: 6KV 8/20us;Izinga lokuvikela: IP40IEC61000-4-2(ESD): ± 8kV ukukhishwa kokuxhumana, ± 15kV ukukhishwa komoyaI-IEC61000-4-3(RS):10V/m(80~1000MHz)I-IEC61000-4-4(EFT): ikhebula lamandla:±4kV;ikhebula ledatha:±2kVI-IEC61000-4-5(Surge):ikhebula lamandla:CM±4kV/DM±2kV;ikhebula ledatha:±4kVIEC61000-4-6(ukudluliselwa kwefrikhwensi yomsakazo):10V( 150kHz~80MHz)

I-IEC61000-4-8(isizinda samandla kazibuthe):100A/m;1000A/m, 1s kuya

3s

I-IEC61000-4-9(inkambu kazibuthe eshayekile):1000A/m

IEC61000-4- 10(i-oscillation emanzi):30A/m 1MHz

IEC61000-4- 12/ 18(shockwave):CM 2.5kV,DM 1kV

I-IEC61000-4- 16 (ukudluliselwa kwemodi evamile): 30V;300V, 1s

I-FCC Ingxenye 15/CISPR22(EN55022):Isigaba B

I-IEC61000-6-2(Izinga Lezimboni Elijwayelekile)

OmakhenikhaIzakhiwo I-IEC60068-2-6 (i-anti vibration)I-IEC60068-2-27 (i-anti shock)I-IEC60068-2-32 (ukuwa kwamahhala)
 Isitifiketi  CCC, CE mark, commercial, CE/LVD EN62368- 1, FCC Ingxenye 15 Ikilasi B,I-RoHS
Ipharamitha Yomzimba
 Ukusebenza kwe-TEMP / Humidity -40~+80°C, 5%~90% RH Ayinciphisi
 Isitoreji TEMP/Umswakama  -40~+85°C, 5%~95% RH Ayifinyeleli
 Ubukhulu (L*W*H) 440mm* 300mm*44mm
 Ukufakwa  Ideskithophu, ukufakwa kwekhabhinethi engu-19 inch 1U 

Usayizi Womkhiqizo:

Umdwebo wohlelo lokusebenza lomkhiqizo:

f67184f96f5651a583754ab9846df20

 

I-Q&A:

Athini amanani akho?

Izintengo zethu zingashintsha kuye ngokuhlinzekwa nezinye izici zemakethe.Sizokuthumelela uhlu lwamanani olubuyekeziwe ngemuva kokuthi inkampani yakho isithinte ukuze uthole imininingwane eyengeziwe.

  Ingabe unenani elincane le-oda?

Yebo, sidinga wonke ama-oda wamazwe ngamazwe ukuthi abe nenani eliqhubekayo le-oda elincane.Uma ufuna ukuthengisa kabusha kodwa ngamanani amancane kakhulu, sincoma ukuthi uhlole iwebhusayithi yethu.

Ungakwazi yini ukunikeza amadokhumenti afanele?

Yebo, singanikeza imibhalo eminingi ehlanganisa Izitifiketi Zokuhlaziya / Ukuvumelana;Umshwalense;Umsuka, namanye amadokhumenti okuthekelisa lapho kudingeka.

Siyini isikhathi sokuhola esimaphakathi?

Kumasampuli, isikhathi sokuhola cishe yizinsuku eziyi-7.Ngokukhiqizwa okukhulu, isikhathi sokuhola siyizinsuku ezingama-20-30 ngemuva kokuthola inkokhelo yediphozithi.Izikhathi zokuhola ziqala ukusebenza lapho (1) sesithole idiphozithi yakho, futhi (2) sinemvume yakho yokugcina yemikhiqizo yakho.Uma izikhathi zethu zokuhola zingasebenzi nomnqamulajuqu wakho, sicela uhlole izidingo zakho ngokuthengisa kwakho.Kuzo zonke izimo sizozama ukwanelisa izidingo zakho.Ezimweni eziningi siyakwazi ukwenza kanjalo.

Yiziphi izinhlobo zezindlela zokukhokha ozamukelayo?

Ungenza inkokhelo ku-akhawunti yethu yasebhange, i-Western Union noma i-PayPal:
Idiphozithi engu-30% kusengaphambili, ibhalansi engu-70% iqhathaniswa nekhophi ye-B/L.

Iyini iwaranti yomkhiqizo?

Sinikeza iwaranti impahla yethu kanye nomsebenzi.Ukuzibophezela kwethu wukwaneliseka kwakho ngemikhiqizo yethu.Ngewaranti noma cha, kuwusiko lwenkampani yethu ukubhekana nokuxazulula zonke izinkinga zamakhasimende ngendlela eyanelisa wonke umuntu.

Ingabe uyakuqinisekisa ukulethwa okuphephile nokuvikelekile kwemikhiqizo?

Yebo, sihlala sisebenzisa ukupakishwa kokuthekelisa kwekhwalithi ephezulu.Siphinde sisebenzisa ukupakishwa kwengozi okukhethekile kwezimpahla eziyingozi kanye nabathumeli abaqinisekisiwe besitoreji esibandayo ezintweni ezizwelayo kukushisa.Izimfuneko zokupakishwa kochwepheshe nezingezona ezijwayelekile zingase zibe nenkokhiso eyengeziwe.

Kuthiwani ngezimali zokuthumela?

Izindleko zokuthumela zincike endleleni okhetha ngayo ukuthola izimpahla.I-Express ngokuvamile iyindlela eshesha kakhulu kodwa futhi ebiza kakhulu.I-Seafreight iyisixazululo esingcono kakhulu samanani amakhulu.Izilinganiso ngqo zempahla singakunikeza kuphela uma sazi imininingwane yenani, isisindo kanye nendlela.Sicela usithinte ukuze uthole ulwazi olwengeziwe.


  • Okwedlule:
  • Olandelayo:

  • Bhala umyalezo wakho lapha futhi usithumelele wona

    Imikhiqizo ehlobene

    • Inethiwekhi egcwele ye-gigabit 16 optical 8 kagesi engu-4 megabit yebanga le-L3 ephethwe switch 6KV yokuvikela umbani

      Igigabit egcwele 16 optical 8 kagesi Amashumi amane amamega...

      Inethiwekhi ephethwe ye-gigabit 16 optical 8 yenethiwekhi ye-gigabit 16 optical 8 yezinga lemboni ye-L3 ephethwe inethiwekhi engu-6KV yokuvikela umbani Izici Zomkhiqizo: Ukufinyelela kwe-Gigabit, i-10G uplink ◇ Sekela ukudlulisela phambili kwentambo okungavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Isekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-10G SFP+ uplink, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene. Ukuphepha ◇ Ukusekela imbobo yokusakaza isitolo...

    • 28-port 10G Uplink L3 Ephethwe I-Industrial Ethernet Switch

      I-28-port 10G Uplink L3 Ephethwe I-Industrial Ethern...

      Izici Zomkhiqizo we-28-port 10G Uplink L3 Ephethwe I-Industrial Ethernet Switch: Ukufinyelela kwe-Gigabit, i-10G uplink ◇ Isekela ukudlulisela phambili kwentambo okungavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Isekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-10G SFP+ uplink, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene. Ukuphepha ◇ Ukusekela ukuhlukaniswa kwembobo.◇ Sekela imbobo yokusakaza ukucindezelwa kwesiphepho.◇ Isekela i-IP+MAC+po...

    • I-Uplink 36-port L3 Managed Industrial Ethernet Switch 4-Port 1/10G SFP

      I-Uplink 36-port L3 I-Industrial Ethernet S...

      Izici Zomkhiqizo ze-Uplink 36-port L3 Ephethwe I-Industrial Ethernet Switch 4-Port 1/10G SFP: Ukufinyelela kwe-Gigabit, i-10G uplink ◇ Sekela ukudlulisela phambili kwentambo okungavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Isekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-10G SFP+ uplink, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene. Ukuphepha ◇ Ukusekela ukuhlukaniswa kwembobo.◇ Sekela imbobo yokusakaza ukucindezelwa kwesiphepho.◇ Sup...

    • I-10G Uplink 36-port L3 Ephethwe I-Industrial Ethernet Switch

      I-10G Uplink 36-port L3 Ephethwe I-Industrial Ethern...

      Izici Zomkhiqizo we-10G Uplink 36-port L3 Ephethwe I-Industrial Ethernet Switch: Ukufinyelela kwe-Gigabit, i-10G uplink ◇ Sekela ukudlulisela phambili kwentambo okungavimbeli.◇ Isekela i-duplex egcwele ngokusekelwe ku-IEEE802.3x kanye ne-half-duplex ngokusekelwe ku-Backpressure.◇ Isekela imbobo ye-Gigabit Ethernet kanye nenhlanganisela yembobo ye-10G SFP+ uplink, eyenza abasebenzisi bakwazi ukwakha inethiwekhi ukuze bahlangabezane nezidingo zezimo ezihlukahlukene. Ukuphepha ◇ Ukusekela ukuhlukaniswa kwembobo.◇ Sekela imbobo yokusakaza ukucindezelwa kwesiphepho.◇ Isekela i-IP+MAC+p...